FREDERICK, Md. — Mission critical cooling manufacturer STULZ Air Technology Systems Inc. has announced the launch of new indirect evaporative cooling equipment (IeCE) that provides high-efficiency environmental control solutions for data centers. Coinciding with this announcement, the company also officially opened the STULZ IeCE Technical Evaluation Center in Frederick, Maryland.

“STULZ IeCE is designed to minimize costly mechanical cooling by optimizing the use of outside air, and the evaporation of water wherever possible,” said Ken Wheeler, global outdoor products manager. “Interest in this type of IDEC (indirect evaporative cooling) solution continues to increase throughout the industry and it is easy to see why. Considering our system, it is possible to achieve a pPUE of 1.03 under ideal environmental conditions. That is a significant efficiency advantage over traditional mechanical cooling.”

STULZ IeCE systems are intended as centralized cooling solutions that are located outside the conditioned space, freeing up valuable square footage within the data center. They are designed to provide efficient and continuous temperature control 24 hours a day, 365 days a year. Indirect evaporative cooling takes advantage of the cooling potential from outside air without introducing contaminants or humidity into the data center. A plate heat exchanger isolates the supply air from the outside air and the evaporation of water is used for cooling.

“Our system uses an aluminum plate heat exchanger,” said Wheeler. “The material provides a significant heat transfer advantage over plastics, and when used with modern higher return temperatures and containment solutions, it allows us to take advantage of cooler outside air extremely efficiently.”

The STULZ IeCE Technical Evaluation Center is an interactive testing facility located at the STULZ manufacturing and design campus in Frederick, Maryland. This test facility allows customers to see STULZ IeCE units and participate in witness testing.

“We are excited to offer our customers the opportunity to see a complete system in operation,” said Joerg Desler, president of STULZ Air Technology Systems. “With this test facility, we will be able to simulate performance with test conditions provided by the engineers and designers we are working with.”

“Our campus in Frederick, Maryland, consists of over 218,000 square feet of design and manufacturing space,” said Wheeler. “We already work very closely with customers to design and customize all types of traditional and outdoor mission critical cooling solutions, and this new test facility extends our capabilities to a whole new level. We are extremely proud of it.”

For more information, visit www.stulz-ats.com.

Publication date: 6/29/2015

Want more HVAC industry news and information? Join The NEWS on Facebook, Twitter, and LinkedIn today!